Vision simulation
One lens, every distance at once.
An implanted lens cannot change focus, so the eye sees far, intermediate and near targets through the same optic at the same moment. Each target's sharpness follows the lens's defocus curve. Look at the chart across the room, the laptop and the phone with X-VIZ, then with a monofocal lens, or split the view to compare.
Far to arm's length,
one continuous range.
The defocus curve stays above high visual acuity from far to about 50 cm, the 2.00 D range of vision. A monofocal reference drops below it within about 2 m.
- Design
- Extended depth of focus
- Optic
- Aspheric · 6.00 mm
- Overall diameter
- 12.50 or 13.00 mm
- Material
- Hydrophobic acrylic
- Refractive index
- 1.49
- Power range
- +5.00 to +30.00 D
- Additional power
- +2.00 D · far + intermediate
- Shelf life
- 3 years
近距离查看 X‑VIZ。
包装、透明晶状体展示和专业品牌形象,专为人工晶状体细分领域而设计。






了解 X‑VIZ
延长焦区的使用体验。
EDOF 将清晰度拉伸到更宽的区域,而不是形成独立的焦点。以下通过互动方式查看这如何转化为视力范围。
X‑VIZ 在病例选择中的位置。
最终的患者适合性始终由外科医生主导。完整适应证、晶状体常数和订货代码,请参阅宣传册。
精细的光学设计,为真实的手术室而生
X‑VIZ 旨在将临床性能与手术实用性相结合:光学设计在外科医生手中用起来可预测。
延长的功能性焦区
旨在以单一光学部体验支持远距离和中距离视力,符合现代患者的期望。
可控的视觉表现
定位为整洁、有把握的选择,许多外科医生偏好将其用于日常满意度方面的沟通。
便于外科医生操作
植入和定位过程中操作感可预测,使精细的光学设计不会带来额外压力。
文件支持
为合作伙伴提供有力的文件支持,以精简接入流程并加快市场启动。
Engineering anatomy
Preloaded, two ways.
The same optic also comes ready inside the injector: in the Agaaz standard preloaded system, or in the Medicel system imported from Switzerland. Neither needs the lens handled. Choose a system and step through its method of use, from viscoelastic to the click-lock.
- Standard incisions
- 2.6 · 2.8 · 3.0 mm
- Medicel incisions
- 2.4 · 2.6 · 2.8 mm
- Standard tip · dock-in
- 2.10 · 2.40 mm
- Tip angulation
- 60° (standard)
- Medicel
- Switzerland · optional haptic pre-folding
- Also supplied
- Butterfly cartridge + injector
Incisions are wound assisted · into the wound · into the bag. Standard method of use: 1, push the plunger forward until the lateral notch is flush with the housing end and it clicks; 2, apply viscoelastic from the distal end to the complete tip, and to the top and bottom of the lens; 3, press the wings together to the click-lock; 4, press the plunger forward until the blue silicone tip reaches the end of the housing. Medicel: viscoelastic into the cartridge and along the lens path, optional haptic pre-folding, then the click-lock wings close and it is ready for delivery.
关键参数一览。
如需完整的技术表、常数和订货代码,请下载宣传册。
已发表文献对景深延长型人工晶状体的论述
这一类产品的临床依据并不依赖于我们自己的资料。以下研究是独立的、经同行评审并被 PubMed 收录的研究,以景深延长型人工晶状体为主题。每个条目都链接到其 PubMed 记录,以便完整阅读原始文献。
- 荟萃分析Trifocal versus extended depth of focus (EDOF) intraocular lenses after cataract extractionTavassoli S et al. (2024) · The Cochrane database of systematic reviews · PMID 38984608
- 荟萃分析Extended Depth of Focus Versus Trifocal for Intraocular Lens Implantation: An Updated Systematic Review and Meta-AnalysisKaram M et al. (2023) · American journal of ophthalmology · PMID 36736751
- 随机对照试验Quality of vision clinical outcomes for a new fully-refractive extended depth of focus Intraocular LensCorbett D et al. (2024) · Eye (London, England) · PMID 38580741
被 PubMed 收录的独立同行评审出版物。作为关于该分子和器械类别的临床背景列出;它们不是对 Agaaz 产品的研究,也不意味着任何背书。