X‑VIZLIO à profondeur de champ étendue
Conçue pour offrir une plage de vision fonctionnelle plus large avec un profil visuel net et contrôlé. Destinée aux chirurgiens qui veulent une optique raffinée sans compromettre la confiance chirurgicale.

Vision simulation
One lens, every distance at once.
An implanted lens cannot change focus, so the eye sees far, intermediate and near targets through the same optic at the same moment. Each target's sharpness follows the lens's defocus curve. Look at the chart across the room, the laptop and the phone with X-VIZ, then with a monofocal lens, or split the view to compare.
Far to arm's length,
one continuous range.
The defocus curve stays above high visual acuity from far to about 50 cm, the 2.00 D range of vision. A monofocal reference drops below it within about 2 m.
- Design
- Extended depth of focus
- Optic
- Aspheric · 6.00 mm
- Overall diameter
- 12.50 or 13.00 mm
- Material
- Hydrophobic acrylic
- Refractive index
- 1.49
- Power range
- +5.00 to +30.00 D
- Additional power
- +2.00 D · far + intermediate
- Shelf life
- 3 years
Découvrez la X‑VIZ de près.
Conditionnement, présentation de la lentille transparente et image de marque professionnelle conçus pour le segment des LIO.






Comprendre l’expérience de focale
étendue de la X‑VIZ.
L’EDOF étend la netteté sur une zone plus large au lieu de créer des foyers distincts. Voici un aperçu interactif de la façon dont cela se traduit en plage de vision.
Place de la X‑VIZ dans le choix des cas.
L’adéquation finale pour le patient relève toujours du chirurgien. Utilisez la brochure pour les indications complètes, les constantes de la lentille et les codes de commande.
Une optique raffinée, conçue pour de vrais blocs opératoires
La X‑VIZ est conçue pour allier performance clinique et praticité chirurgicale : une optique dont le comportement est prévisible dans la main du chirurgien.
Focale fonctionnelle étendue
Conçue pour soutenir la vision de loin et intermédiaire dans une seule expérience optique, alignée sur les attentes des patients modernes.
Profil visuel contrôlé
Positionnée comme une offre nette et assurée que de nombreux chirurgiens préfèrent pour les échanges de satisfaction au quotidien.
Manipulation adaptée au chirurgien
Conçue pour paraître prévisible à la délivrance et au positionnement, afin qu’une optique raffinée ne s’accompagne pas de stress supplémentaire.
Documentation
Une aide documentaire solide pour les partenaires, alignée sur une intégration simplifiée et une activation de marché plus rapide.
Engineering anatomy
Preloaded, two ways.
The same optic also comes ready inside the injector: in the Agaaz standard preloaded system, or in the Medicel system imported from Switzerland. Neither needs the lens handled. Choose a system and step through its method of use, from viscoelastic to the click-lock.
- Standard incisions
- 2,6 · 2,8 · 3,0 mm
- Medicel incisions
- 2,4 · 2,6 · 2,8 mm
- Standard tip · dock-in
- 2,10 · 2,40 mm
- Tip angulation
- 60° (standard)
- Medicel
- Switzerland · optional haptic pre-folding
- Also supplied
- Butterfly cartridge + injector
Incisions are wound assisted · into the wound · into the bag. Standard method of use: 1, push the plunger forward until the lateral notch is flush with the housing end and it clicks; 2, apply viscoelastic from the distal end to the complete tip, and to the top and bottom of the lens; 3, press the wings together to the click-lock; 4, press the plunger forward until the blue silicone tip reaches the end of the housing. Medicel: viscoelastic into the cartridge and along the lens path, optional haptic pre-folding, then the click-lock wings close and it is ready for delivery.
Les paramètres clés en un coup d’œil.
Pour le tableau technique complet, les constantes et les codes de commande, utilisez le téléchargement de la brochure.
Ce que dit la littérature publiée sur les LIO à profondeur de champ étendue
L’argument clinique en faveur de cette catégorie de produits ne repose pas sur nos propres documents. Les études ci-dessous sont indépendantes, évaluées par les pairs et indexées dans PubMed, et elles portent sur les LIO à profondeur de champ étendue en tant que sujet. Chaque entrée renvoie à sa fiche PubMed afin que la source primaire puisse être lue en entier.
- Méta-analyseTrifocal versus extended depth of focus (EDOF) intraocular lenses after cataract extractionTavassoli S et al. (2024) · The Cochrane database of systematic reviews · PMID 38984608
- Méta-analyseExtended Depth of Focus Versus Trifocal for Intraocular Lens Implantation: An Updated Systematic Review and Meta-AnalysisKaram M et al. (2023) · American journal of ophthalmology · PMID 36736751
- Essai contrôlé randomiséQuality of vision clinical outcomes for a new fully-refractive extended depth of focus Intraocular LensCorbett D et al. (2024) · Eye (London, England) · PMID 38580741
Publications indépendantes évaluées par les pairs et indexées dans PubMed. Présentées comme contexte clinique sur la molécule et la classe de dispositifs ; ce ne sont pas des études sur des produits Agaaz et n’impliquent aucune recommandation.
Questions courantes sur
les lentilles intraoculaires EDOF.
Amenez la X‑VIZ sur votre marché
Indiquez votre segment cible, vos volumes mensuels et votre répartition de lentilles préférée. Nous répondrons avec les tarifs, le délai de livraison et le dossier documentaire adapté à votre voie.