Skip to Content
i‑Nera — Hydrophilic Foldable Aspheric IOL | Premium Cataract Lens | Agaaz Ophthalmics
AGAAZ OPHTHALMICS
AsphericHydrophilicFoldable

i‑Nera

Hydrophilic foldable aspheric IOL — precision-engineered for predictable centration, smooth micro-incision injection, and consistent postoperative clarity across a broad patient base.

6.0
Optic Diameter (mm)
13.0
Overall Length (mm)
C‑Loop
Modified Haptic Design
i‑Nera Hydrophilic Foldable Aspheric IOL by Agaaz Ophthalmics
Aspheric OpticReduced Aberrations
HydrophilicSmooth Unfolding
PreloadedInjector Ready
TECHNICAL SPECIFICATIONS

Engineering clarity.

Built on hydrophilic acrylic with an optimised aspheric profile for predictable visual outcomes in routine cataract surgery.

Lens Type

Foldable Aspheric IOL
Hydrophilic acrylic material platform

Optic design

Aspheric Profile
Reduced spherical aberration, enhanced contrast

Optic diameter

6.0 mm
Wide optical zone for quality vision

Overall length

13.0 mm
Modified C-loop haptic geometry

Diopter range

Wide Range
Custom diopter mixes supported per catalogue

Delivery

Preloaded / Injector
Micro-incision ready, smooth implantation
CLINICAL ADVANTAGES

Why surgeons choose
hydrophilic aspheric.

i‑Nera addresses the core priorities of routine cataract surgery — predictable centration, optical clarity, and surgeon-friendly handling.

Aspheric Optic Precision

The optimised aspheric profile reduces spherical aberrations and enhances contrast sensitivity — supporting clear functional vision from reading to driving in varying light conditions.

Optical Quality

Predictable Centration

Modified C-loop haptic design with balanced memory ensures stable positioning within the capsular bag — reducing the risk of decentration and tilt that can affect refractive outcomes.

Stability

Smooth Injection & Unfolding

Hydrophilic acrylic material provides reliable flexibility for smooth injection through micro-incisions and consistent, controlled unfolding inside the capsular bag — reducing surgical chair time.

Handling

Long-Term Visual Stability

Material and design selected for biocompatible performance and postoperative clarity across a broad patient base — supporting dependable outcomes in high-volume cataract programmes.

Durability
SURGICAL WORKFLOW

Where i‑Nera fits.

Integrated at the IOL implantation step — designed for routine cataract phacoemulsification workflows.

1

Incision

Micro-incision entry

2

Rhexis

Anterior capsule opening

3

Phaco

Nucleus removal

i‑Nera

IOL implantation

5

OVD

Viscoelastic removal

6

Close

Wound hydration

Interested in i‑Nera?

Contact Agaaz Ophthalmics for pricing, regulatory documentation, diopter availability, or distribution partnership enquiries.