X‑VIZExtended Depth of Focus IOL
Built to deliver a wider functional range of vision with a clean, controlled visual profile. Designed for surgeons who want refined optics without compromising surgical confidence.

Vision simulation
One lens, every distance at once.
An implanted lens cannot change focus, so the eye sees far, intermediate and near targets through the same optic at the same moment. Each target's sharpness follows the lens's defocus curve. Look at the chart across the room, the laptop and the phone with X-VIZ, then with a monofocal lens, or split the view to compare.
Far to arm's length,
one continuous range.
The defocus curve stays above high visual acuity from far to about 50 cm, the 2.00 D range of vision. A monofocal reference drops below it within about 2 m.
- Design
- Extended depth of focus
- Optic
- Aspheric · 6.00 mm
- Overall diameter
- 12.50 or 13.00 mm
- Material
- Hydrophobic acrylic
- Refractive index
- 1.49
- Power range
- +5.00 to +30.00 D
- Additional power
- +2.00 D · far + intermediate
- Shelf life
- 3 years
See X‑VIZ up close.
Packaging, clear lens presentation, and professional branding designed for the IOL segment.






Understanding the X‑VIZ
extended focus experience.
EDOF stretches clarity across a wider zone instead of creating separate focal points. Here's an interactive look at how that translates to vision range.
Where X‑VIZ fits in case selection.
Final patient suitability is always surgeon-led. Use the brochure for full indications, lens constants, and ordering codes.
Refined optics, built for real operating rooms
X‑VIZ is designed to combine clinical performance with surgical practicality — optics that feel predictable in the surgeon's hands.
Extended functional focus
Designed to support distance and intermediate vision in a single optic experience, aligned to modern patient expectations.
Controlled visual profile
Positioned for a clean, confident offering that many surgeons prefer for day‑to‑day satisfaction conversations.
Surgeon-Friendly Handling
Built to feel predictable in delivery and positioning, so refined optics don’t come with added stress.
Documentation support
Strong documentation support for partners, aligned to streamlined onboarding and faster market activation.
Engineering anatomy
Preloaded, two ways.
The same optic also comes ready inside the injector: in the Agaaz standard preloaded system, or in the Medicel system imported from Switzerland. Neither needs the lens handled. Choose a system and step through its method of use, from viscoelastic to the click-lock.
- Standard incisions
- 2.6 · 2.8 · 3.0 mm
- Medicel incisions
- 2.4 · 2.6 · 2.8 mm
- Standard tip · dock-in
- 2.10 · 2.40 mm
- Tip angulation
- 60° (standard)
- Medicel
- Switzerland · optional haptic pre-folding
- Also supplied
- Butterfly cartridge + injector
Incisions are wound assisted · into the wound · into the bag. Standard method of use: 1, push the plunger forward until the lateral notch is flush with the housing end and it clicks; 2, apply viscoelastic from the distal end to the complete tip, and to the top and bottom of the lens; 3, press the wings together to the click-lock; 4, press the plunger forward until the blue silicone tip reaches the end of the housing. Medicel: viscoelastic into the cartridge and along the lens path, optional haptic pre-folding, then the click-lock wings close and it is ready for delivery.
Key parameters at a glance.
For the complete technical table, constants, and ordering codes, use the brochure download.
What the published literature says about extended depth of focus iols
The clinical case for this product category does not rest on our own material. The studies below are independent, peer-reviewed and indexed in PubMed, and they cover extended depth of focus iols as a subject. Each entry links to its PubMed record so the primary source can be read in full.
- Meta-AnalysisTrifocal versus extended depth of focus (EDOF) intraocular lenses after cataract extractionTavassoli S et al. (2024) · The Cochrane database of systematic reviews · PMID 38984608
- Meta-AnalysisExtended Depth of Focus Versus Trifocal for Intraocular Lens Implantation: An Updated Systematic Review and Meta-AnalysisKaram M et al. (2023) · American journal of ophthalmology · PMID 36736751
- Randomized Controlled TrialQuality of vision clinical outcomes for a new fully-refractive extended depth of focus Intraocular LensCorbett D et al. (2024) · Eye (London, England) · PMID 38580741
Independent peer-reviewed publications indexed in PubMed. Listed as clinical background on the molecule and device class; they are not studies of Agaaz products and imply no endorsement.
Common questions about
EDOF intraocular lenses.
Bring X‑VIZ to your market
Share your target segment, monthly volumes, and preferred lens mix. We’ll respond with pricing, lead time, and the documentation pack aligned to your route.